|
 |
Sprache wählen - select language kies taal-elija la lengua-vibrat jazik |
|
|
| Advertising-Bonus-System, click here. |
|
| Shopping Cart |
 |
|
|
|
|
 Customer group:Guest
|
|



Mit Kreditkarte sicher zahlen - PayPal wählen.
 Besucher dieses Jahr |
|
| Contents |
| |
- Product Introduction
- Characteristics of the Product
- Notices to Users
- Cautions
- Description of the Product
- How to Use
- Suitable User and forbidden user
- Troubleshooting
- Instructions to Atomized cartridge
- How to abstain from smoking by using this product?
|
| Product Introduction |
| |
|
The Electronic Cigarette is a non-flammable electronic atomizing device, adopts the advanced microelectronic technology and supercritical physical atomized technology, to atomize the high-purity nicotine diluents, which is extracted from tobacco and has the excitatory function, so that smoker can take it in.
The liquid in the cartridge contains nicotine, perfumery compounds special for cigarette and ordinary food additives. It’s provided with efficacies similar to those of the ordinary cigarette. It can refresh the smokers and satisfy their smoking addiction, making them happy and relaxed, so as to relief the suffering of quitting smoking. The essentially differences between the Electronic Cigarette and the ordinary cigarettes are as follows:
- No tar and other carcinogenic substance or harmful ingredients to human body.
-
No ignition required, without the danger hence will not lead to the over 4000 chemical substance produced by the ordinary cigarettes, like carbon monoxide.
- Harmless to other and the environment, without the danger of second-hand smoking.
- No possibility to cause fire. It can be used safely in most No-smoking palaces.
-
According to the smoke-quitting procedure, the target of quitting smoke can reached non-painfully within a certain period of time.
|
| Characteristics of the Product |
| |
-
No ignition and no fire hazard. Free of tar and other carcinogenic substance of harmful ingredients.
-
Humanized design, the temperature of the simulative smog is similar to that of the human body.
-
No environmental pollution. The exhaled smoke is a kind of gas dispersed generated during the atomization of tobacco alkaloid liquid; so there is no harm from hence second-hand smoke.
-
The electromagnetic wave is shielded so as to avoid electromagnetic radiation.
-
Contain high-purity nicotine, designed based on the WHO-recommended Nicotine Replacement Therapy; enable smokers to abstain from smoking non-painfully.
-
The nicotine content per electronic cigarette cartridge is less than that of 20 ordinary cigarettes, and the state of discontinuous liquid supply specially designed prevents smokers from smoking continuously by this device, thus, reducing the use frequency and protecting the smokers’ health.
-
Working temperature: ambient temperature from – 5C to 42C, with a wide serviceable range.
|
| Notices to Users |
| |
-
The special components must be used and the proper operation procedures must be followed to prevent any unnecessary malfunction and damage of the product, such as cartridge, lithium battery and charger.
-
Pay attention to correct battery installation for anode and cathode before using and charging.
-
Replace the cartridge with a new one as the smoker volume is reduced.
-
If the indicator light turns dim, Please replace the battery with a full charged.
-
The charger can work in a normal condition with the voltage at AC100V-240V, 50/60 Hz.
-
Keep the Electronic Cigarette separated from other articles and avoid collision.
-
The Electronic Cigarette is completely free from second-hand smoking, absolutely harmless to the surrounding people and the environment. It never needs to be lighted and is without the hidden danger of fire accident. So it can be safely used in public places.
-
After finishing the Four-step method for quitting smoking, it is forbidden to use the cartridge containing nicotine. If you use it continuously. it’s better to use the cartridge without nicotine.
-
Once some problem occurs in this product, please have it repaired in the designated repair sites, and don’t dismantle it by yourself, which will bring damages to it and endanger yourself.
|
| Caution |
| |
-
Keep at away from high temperature environment in use or storage.
-
Keep it and its special components out of children’s reach, and avoid improper operation. And properly keep the dismountable fitting, like battery cover, atomized cartridge, battery and charger, which may cause dangers to children once being swallowed.
-
For people with adverse reaction after using this product, it is recommended to use the cartridge with lower nicotine content or no nicotine.
-
Please protect mucous membrane from direct contact with the nicotine liquid contained in the atomized cartridge.
-
Please properly keep the charged battery, and prevent it from mixing with metal articles in your pocket, wallet or the other bags. The conductors can bring about short circuit, heating or damages to the battery.
-
It’s better to use the Electronic Cigarette smoking accordant to the time and frequency of smoking a ordinary cigarette.
-
Please strictly abide by relevant local laws and regulations on driving. Don’t use the Electronic Cigarette while driving, and keep it properly to avoid damages to it caused by collision.
-
When try to clean the charger. You must unplug it from the power supply beforehand. It is absolutely prohibited to handle the charger outdoors or in a damp environment.
|
| Description of the Product |
| |
-
Structure of the body (Atomizing Device)
The body is an integral structure consisting of stainless shell, lithium battery drawer, microelectronic circuit, high-sensibility sensor, and atomization chamber. An operating mode indicator light at tip of the atomizing device.
-
Atomized cartridge
The atomized cartridge is composed of an inhaler and liquid container. The liquid container contains nicotine diluents which is ready for atomized; it doesn’t contain ingredients harmful to human body, such as tar and carcinogenic substance.
The inhaler and liquid container are disposable.
According to nicotine content, the atomized cartridges are classified into four kinds: high, medium, low and zero. Cartridge with high, medium or low nicotine content are only used as the substitute for cigarette during the process of smoke abstention, and the cartridge free of nicotine is for long-term use.
In order to protect the public environment, please don’t throw away the cartridge shell optionally
-
Battery and Charger
The Electronic Cigarette employs a 3.6V special lithium battery and special charger, which cannot be replaced by other lithium battery and charger. The input supply voltage of the changer: AC100-240V, 50/60 Hz. Attention shall be paid to whether the rated value of local supply voltage is accordant to that of this charger or not during travelling. The circulator using frequency of the battery will be no less than 300 times.
|
| How to Use |
| |
Inserting the battery:
- Step 1: Unscrew the battery cover;
- Step 2: Insert the battery with its cathode inward and anode outward;
- Step 3: Screw down the battery cower.
Unwrap the cartridge:
- Step 1: Remove the cover;
- Step 2: Take the cartridge out from the sheath;
- Step 3: Unscrew and remove the sealed cap.
Put the cartridge into the body (Atomizing Device)
- Step 1: Unscrew and remove an inhaler with cover on body;
- Step 2: Put the new cartridge into the body and screw down.
The product will be standby state while you put the battery into the body and screw in the cartridge.
Operating mode:
The electronic circuit will start to work as the Electronic Cigarette is inhaled by mouth. And the indicator light at tip of the product will be lit simultaneously. Stop inhaling will terminate the atomization, and the operating mode will turn to standby state. It is recommended to place it horizontally and don’t keep it upwards, so as to prevent you from inhaling the liquid into your mouth, which many cause stimulus to your oral mucosa. When the indicator light is dimming, it indicates the need to replace the battery.
Smoking method
Smokers smoke each ordinary cigarette by 14-16 mouthfuls, so after smoking 14-16 mouthfuls (equal to a ordinary cigarette) of the atomized cartridge, smoker should stop smoking about half an hour before smoking again.
Function recovery mode:
After the product has been used for 20 to 30 days, if the atomization volume is still reduced obviously even if a new cartridge is used and the battery is full charged, please take out the cartridge and insert a pin or clip into the front-end hole lightly and hold it for 10 seconds during each insertion; in the meantime the indicator light is on. Such not perform this recovery function too frequently. (See the illustration)
Directions for use of battery and charger:
If the indicator light turns dim obviously during use, recharge the battery with the special charger. Please verify the polarity of the battery before charging. Don’t put it in reversely. After the battery has been charged for 3 to 4 hours, the battery is fully charged when the indicator light turns green from red. Take the battery out and cut off the charger’s power supply.
Precautions for use of battery and charger
-
Keep the battery away from high temperature source while charging.
-
Don’t connect anode and cathode of the battery with metal, to prevent short circuit.
-
Do not weld the battery directly and pierce through the battery with nails or other edge tool.
-
In case of battery’s leakage happens, if your eye contacts with electrolyte leaking from the battery, don’t rub it. electrolyte from leaking the battery, don’t rub it. Please wash it with clean water immediately and ask for doctor’s helps.
-
If the battery peculiar smells. Burns, changes color, deforms or any other unusual case happen during charging, cut off the power supply, and take the battery out from the device or charger and stop using.
-
The charger can be used for the special lithium battery of the Electronic Cigarette only; please don’t attempt using this charger to charge other types of batteries.
-
The first charging must be kept for 8 hours, and the normal charging tome should be 3-4 hours.
-
If the Electronic Cigarette is not to be used for a long period of time, take the battery out from the device or charger. Keep the battery stored alone in a low temperature and dry please after fully charged.
|
| Suitable User and forbidden user |
| |
- Suitable User
-
The people who have been smoking for a long period of time, and suffering uncomfortable feeling.
-
The people working in no-smoking places with the habit of smoking.
-
The smokers who want to quit smoking, Painless smoking abstention can be realized gradually by decreasing nicotine content.
- Forbidden User
- Minors under 18 years old.
- People without the habit of smoking.
- People sensitive to nicotine or any other ingredients in the inhalant.
- Pregnant and breast feeding women.
- The patients who should avoid smoking.
|
| Troubleshooting |
| |
-
When the indicator light turns dim obviously during use, please change a charged battery.
-
When the smoke volume is reduced, please change cartridge of battery.
-
After the product has been used for 20 to 30 days, if the atomization volume is still reduced obviously even if a new cartridge is used and the battery is fully charged, the function recovery mode may be used.
Note: After above solution, if the failures still remain or you feel uncomfortable during use, please stop using immediately, and contact the sales agent or our company.
|
| |
| Instructions to Atomized cartridge |
| |
| About atomized cartridge contains nicotine.
The atomized cartridge contains nicotine. The nicotine is the kind of natural alkaloid extracted from tobacco leaf or other plants containing nicotine, It is the main substance that makes smokers addicted. When a person is smoking, nicotine comes into the blood and then in just 7-9 seconds, and now smokers will respond with a series of physiological reaction such as happiness. These years, nicotine replacement therapy has been demonstrated to be safe and affective way for smoke abstention, according to experts and many clinical experiments. Free from harmful substance such as tar and carbon monoxide, the atomized cartridge can minimize the smoking harms for most smoke-quitters; while at the same time, it can also release the quitter from discomfort reaction during smoke abstention, for it contains just a small quantity of high purity nicotine. The virulence testing of the atomized cartridge by poison test of several authoritative organizations has demonstrated its safety.
How many cigarettes are equal to one atomized cartridge?
Different smoking habits of individual smoker an various brands cigarettes result different levels of nicotine contents. For example, usually the marking on ordinary cigarette packet is marked by 1.1 mg nicotine, indicating that each cigarette in the box contains 1.1. mg nicotine. Thus, one package of ordinary cigarette (20 branches) contains nicotine is equal to 1.1 mg x 20 = 22 mg. One atomized cartridge can be sucked is lower than 300 mouthfuls, equivalent to one package of ordinary cigarette (20 branches) approximately. But the nicotine content is lower than ordinary cigarette with the equivalent cigarette potency. According to nicotine content, the atomized cartridges are classified into four kinds: high, medium, low and zero.
- HIGH (nicotine content: 18 mg)
- MED (nicotine content: 14 mg)
- LOW (nicotine content: 11 mg)
- NO (nicotine content: 0 mg)
Notices for use of cartridge
-
Read the instructions carefully before using the atomized cartridge.
-
The atomized cartridge is the special accessory and must be used with Electronic Cigarette only.
-
The atomized cartridge is a kind of disposable product, do not reuse. Please dispose of it properly after use, and keep it out of children’s reach.
Precautions for use of cartridge
-
Storage: keep in a cool and dry place; Shell life: 24 months.
-
Please keep it out of children’s reach.
-
Please use before the expiry date printed on the package.
-
Do not put it into mouth or contact with mucous membrane.
-
Use unsuitable for smoking is not allowed to use this product.
-
Nicotine and atomizing agent in the cartridge shall be prepared strictly in correct proportion; mixing with other liquid is forbidden.
|
| How to abstain from smoking by using this product? |
| |
|
The atomized cartridge is designed according to Nicotine replacement therapy recommended by World Health Organization (WHO). It will let smokers gradually step-down the quantity of nicotine they absorbed. It is recommended that users try the cartridge starting with he cartridge without nicotine, and then realize the painless abstention via nicotine descending method as long as finding out suitable nicotine content.
Four-step method of abstention from smoking:
- Step 1: Use the cartridge with high nicotine content for 6 weeks by normal smoking habit;
- Step 2: Use the cartridge with medium nicotine content for 12 weeks by normal smoking habit;
- Step 3: Use the cartridge with low nicotine content for 4 weeks by normal smoking habit;
- Step 4: Finally, use the cartridge without nicotine for 2 weeks to achieve the goal of smoke abstention.
This method applies to people who have strong desire to quit smoking. The feels and time of every step may be different according to different people.
|
|
 |
|
|
|